Load Testing

Hello,
 
I am in Texas and have a question regarding load testing multiple cranes (in this case 2) on a single runway. This is a new install - 20 Ton freestanding runway designed for two 10 Ton cranes right next to each other. Normally each crane would be tested @ 125% individually.
 
Does this satisfy all ANSI/OSHA requirements? or should both cranes be tested at the same time?
 
 
Thanks

 

What did you think of this article?




Trackbacks
  • No trackbacks exist for this post.
Comments
Page: 1 of 1
  • 9/27/2008 6:47 AM Richard Wehrmeister wrote:
    Carl

    Proof testing both cranes at the same time is not a requirement as far as OSHA/ASME is concerned. If your trying to prove that the runway is designed to handle 2 loaded 10 ton cranes at capacity between support columns then this structure can only be certified by an engineer. Since this is a new system engineered drawings should be available to confirm the runway design.
    Reply to this
    1. 9/27/2008 4:44 PM Carl wrote:
      Richard,
      Thanks for the reply. And yes the structure and the footers are designed fot the loading of the 2 - 10 Ton cranes within in the same bay spacing.

      However, just to satisfy the end user, we will test each crane @ 125%, then load each crane w/ 20,000# to test the runway @ 100%.

      Carl
      Reply to this

Page: 1 of 1
Leave a comment

Submitted comments are subject to moderation before being displayed.

 Enter the above security code (required)

 Name (required)

 Email (will not be published) (required)

 Website